HST 216/343/640/1000 BDS Dual Dust & Sand Chamber

Description

Nviro Solutions Dust Chambers are made for the simulation of Dust and Sand conditions in a controlled atmosphere.

Standard

MIL STD 810F - Method 510.4.Para 4.2.2, Procedure 1 - Blowing Dust

MIL STD 810F - Method 510.4.Para 4.2.3, Procedure II - Blowing Sand

Features

  • Interior of chamber made of high quality stainless steel (SUS#304). Exterior of chamber is made of solid baked painted Steel plate. Interior of chamber treated with high temperature protection material. Chamber body connected to ground for ant-static protection.
  • The Airflow Cycle System uses Baked Painted Steel Plate with over temperature protection.
  • High pressure air circulating fan for wind speed 1.0 ~ 29.0 m/s attached with a wind speed adjustor.
  • Electric heater with SSR & PID control for constant temperature.
  • Dust Supplementary Device used for automatically adjusting the dust volume based on set values.
  • Automatic Dry Air Handling System
  • Chamber is well sealed and sealing must be maintained at all times to meet the environmental requirements of Dust/Sand and Powder exhaust.
  • Control System consists of Temperature Control Unit, Humidity Control Unit, Wind Speed Control Unit and Concentration Control Unit.
  • Control Panel consists of LED Controller (Other Options available) and DATA Collection.
  • Uses electronic concentration sensors to automatically adjust and set dust and sand consistency levels.

Specifications

Specification Specification in US Specification in Metric
Temperature Range 73.4°F to 158°F (tolerance ?± 2°F) 23°C to 70°C (tolerance ?± 2°C)
Humidity Range <30% RH <30% RH
Air Speed 1.0 to 10.0 m/s (Procedure I) 18.0 to 29.0 m/s (Procedure II) 1.0 to 10.0 m/s (Procedure I) 18.0 to 29.0 m/s (Procedure II)
Dust & Sand Consistency 3.0 to 17.6 g/m³ (10.7 ± 7 g/m³) (Procedure I) 0.18 + 0.2 g/m³; 1.1 ± 0.3 g/m³; 2.2 ± 0.5 g/m³ (Procedure II) 3.0 to 17.6 g/m³ (10.7 ± 7 g/m³) (Procedure I) 0.18 + 0.2 g/m³; 1.1 ± 0.3 g/m³; 2.2 ± 0.5 g/m³ (Procedure II)
Interior Dimension 23.6W x 23.6H x 23.6D IN 600W x 600H x 600D mm
Exterior Dimension 165W x 86.6H x 78.7D IN (approx.) 4200W x 2200H x 2000D mm (approx.)
Door 31.5W x 27.6H IN (Single Door) 800W x 700H mm (Single Door)
Observation Window 11.8W x 11.8H IN 300W x 300H mm
Power Sources 380/440/480VAC/50/60Hz 380/440/480VAC/50/60Hz